fleetd: report a lead's live context usage in fleet_list #602

Merged
ltms merged 4 commits from worker/lead-context-gauge-ad404f-1 into main 2026-09-20 11:38:31 +02:00

4 Commits

Author SHA1 Message Date
ltms 3762aca307 Merge #606: wire the lead context gauge to the real configDir, and stop flapping on a torn line
CI / shell-tests (pull_request) Failing after 6s
CI / build (pull_request) Failing after 1m21s
CI / contract (pull_request) Successful in 1m50s
Fixes the two defects recorded in #602's own body.

1. FleetMcp.contextView passed configDir=null, so the gauge read <user.home>/
   .claude while this host's lead profile sets an override. Measured before the
   fix: 19 transcripts under the real directory, 0 under the fallback. The gauge
   would have deployed green and reported UNKNOWN forever, for every lead.
   Now threaded via FleetMcp.LeadConfigDirSource, built by Fleetd
   .leadConfigDirSource, following fleet.leaders.<name>.profile to that
   profile's configDir and reading config.get() live inside the lambda.

2. A torn final line no longer means UNKNOWN. fleet_list reads a transcript
   Claude Code may be mid-write on, so the last line can be cut. The old code
   treated that as fatal, which would make the gauge flap at random. The stated
   reason ("a format change should show as UNKNOWN") does not hold: a real
   format change makes EVERY line unparseable, and that case is still caught.

Verified by the lead on the combined state with current main merged in, not on
the branch alone: mvn -o clean install exit 0, 147 reports, 1841 tests, 0
failures, 0 errors, 0 skipped.

Mutation-checked independently by the lead:
  Fleetd.leadConfigDirSource body -> none()   -> KILLED (1 failure)
  FleetMcp.contextView configDir -> null      -> KILLED (worker-measured)

KNOWN RESIDUAL, documented rather than overclaimed. main's own one-line call to
leadConfigDirSource could be swapped for none() and the suite stays green. Every
member of this wiring-test family (loopHealthSource, capacitySource,
healthCoverageSource) has the identical gap — no test runs Fleetd.main far enough
to observe which factory it called. Filed separately as a class-wide problem
rather than patched here. The empirical close is the dogfood check after redeploy.
2026-09-20 11:38:22 +02:00
Dai Ha 4e27bde2d7 fleetd #602 gauge-wiring follow-up: pin Fleetd.main's LeadConfigDirSource wiring
Extract the inline new FleetMcp.LeadConfigDirSource(leadConfigDirLookup(...))
construction in Fleetd.main into a package-private factory,
Fleetd.leadConfigDirSource, mirroring loopHealthSource/capacitySource/
healthCoverageSource. Add FleetdLeadConfigDirSourceWiringTest, which calls the
factory directly with real Profile/Leader fixtures and asserts the returned
source resolves a real configDir -- a property that is false if the factory's
body is mutated to return LeadConfigDirSource.none().

Neither FleetMcpLeadContextGaugeWiringTest nor FleetdLeadConfigDirLookupTest
could catch main losing this wiring: each builds its own instance instead of
calling what main calls. This closes that gap at the factory level, matching
the standard already accepted for loopHealthSource's own wiring test.
2026-09-20 16:34:49 +07:00
Dai Ha d345b14e43 fleetd #602 gauge-wiring: thread a lead's configured configDir into the context gauge
FleetMcp.contextView hardcoded LeadContextGauge.read(null, ...), so a lead whose
profile sets its own CLAUDE_CONFIG_DIR always read the wrong transcript directory
and reported UNKNOWN forever, with no error anywhere.

- Add FleetMcp.LeadConfigDirSource (same idiom as LeadSeatSource) and thread it
  through the constructor / listFleet overload chain / leadView / contextView.
- Add Fleetd.leadConfigDirLookup, wired at construction, following the same
  fleet.leaders.<name>.profile link leadSeatLookup already uses, one step
  further to that profile's own configDir.
- LeadContextGauge.parse: a single unparseable line (typically the final one,
  torn by a write this read raced) is now skipped rather than forcing UNKNOWN;
  only when every line in the read window fails to parse does it report
  UNKNOWN, which is the real format-change signal.
- Tests: FleetdLeadConfigDirLookupTest (lookup logic), FleetMcpLeadContextGaugeWiringTest
  (end-to-end: config naming directory A vs B decides which is read; a lead with
  no configured dir degrades without throwing), and two replacement properties in
  LeadContextGaugeTest for the torn-line fix plus its all-unparseable control.
2026-09-20 16:19:37 +07:00
Dai Ha 3ed7bfca67 fleetd: report a lead's live context usage in fleet_list
CI / shell-tests (pull_request) Failing after 7s
CI / build (pull_request) Failing after 1m37s
CI / contract (pull_request) Successful in 2m7s
fleetd had no way to see how full a lead's context window is. On this host a
lead auto-compacted 30 times in one session, discarding roughly 250,000 tokens
and costing 46s to 3m16s each time, and nothing could see it coming.

LeadContextGauge reads the transcript Claude Code itself writes, never the
lead's pane. It finds <sessionId>.jsonl by NAME under <configDir>/projects/
rather than deriving the project slug, which is an undocumented internal.

Three states, not two: OK, HIGH, UNKNOWN. Every path that cannot positively
establish a token count reports UNKNOWN with no number, so a lead is never
told it is fine when the honest answer is "I could not look".

Bounded two ways: TAIL_BYTES caps bytes read off disk, and a 5s cache TTL caps
how often that read happens, because fleet_list is polled constantly.

Recovered by the lead: the authoring member ended on a backend error (DNS
ENOTFOUND) with this work uncommitted and unpushed in its worktree. Verified
before committing: mvn -o clean install exit 0, 1813 tests, 0 failures,
0 errors, 0 skipped, 144 reports; LeadContextGaugeTest 8/8.

KNOWN INCOMPLETE - see the PR. The fleet_list call site passes configDir=null,
which falls back to ~/.claude, but this host's lead profile sets configDir to
an override. Measured: 19 transcripts under the real configDir, 0 under the
fallback. The gauge is therefore INERT on this fleet until that is wired.
2026-09-20 16:05:15 +07:00