Dai Ha ac351ee1de fleetd #501: readiness-grace expiry logs measured elapsed time and the loop's own poll counter, never the configured budget
CI / contract (pull_request) Successful in 49s
CI / build (pull_request) Successful in 2m2s
The line at Injector.java:383-387 printed two numbers that read as measurements
but were both compile-time constants: READINESS_GRACE_POLLS for the poll count
(the loop's own Target.notReadySincePoll counter was in scope at the same call
site), and READINESS_GRACE_POLLS * POLL_INTERVAL_MILLIS / 1000 for the elapsed
time — arithmetic on two constants, never a measurement, and wrong in the
direction that says everything ran on schedule.

Fix, copying the LongSupplier-clock shape LeadRollover already uses:
- print t.notReadySincePoll instead of the constant for the poll count (the two
  agree by construction on this branch, so no test can tell them apart — the
  comment says so honestly).
- add Target.notReadySinceMillis, stamped at the first non-ready sample and
  reset at all three sites notReadySincePoll already resets (:304, :355, :389
  pre-fix line numbers), to compute a real elapsed time at expiry.
- inject a LongSupplier nowMillis (defaulting to System::currentTimeMillis)
  through new package-private constructor overloads so a test can supply a
  clock whose advance does not track POLL_INTERVAL_MILLIS.

Tests use a ListAppender to assert on the log message contents, per
LeadRolloverTest's pattern. The elapsed-time test drives the loop with a stub
clock returning two literal, non-derived values so it can fail if the fix
regresses to the constant-arithmetic line — proved by mutation: reverting the
elapsed calculation to READINESS_GRACE_POLLS * POLL_INTERVAL_MILLIS turns that
one test red (1 failure); reverting the poll-count print to the constant is an
equivalent mutant (0 failures), because the counter and the constant are
identical at that exact call site by construction.

fleetd clean install: Tests run: 1683, Failures: 0, Errors: 0, Skipped: 0.
2026-09-12 09:57:57 +07:00
ltms 8f59019305 Merge #496: lead-rollover logs measured elapsed time and measured counts, never the configured budget (fleetd #494)
CI / contract (push) Successful in 1m14s
CI / build (push) Successful in 2m1s
Three commits. All verified by the lead in a detached worktree, not taken from the worker's report.

3fb3311 — the /clear-settle and success paths return measured elapsed time and a real nudge count
c87cc25 — print the measured nudge count; fix the same defect on the sibling turn-settle timeout line
e966cba — the poll count on the same line was still a constant; the test could not tell the difference

Lead verification at e966cba:
  mvn clean install -> Tests run: 1681, Failures: 0, Errors: 0, Skipped: 0, BUILD SUCCESS
  LeadRolloverTest  -> Tests run: 33, Failures: 0, Errors: 0, Skipped: 0
  Gitea CI on e966cba: success

Mutation M2 (PICKUP_GRACE_POLLS 8 -> 5), run by the lead: 2 failures,
clearGraceReleaseLogIsWarnWithMeasuredElapsed and successLogPrintsMeasuredElapsedForTheWholeRoll.
The emitted line under the mutant read "after 5 consecutive IDLE/DONE polls (4 of those were
nudged)", so both numbers now follow the loop. Restored, shasum byte-identical, control 33/0 green.

Known and deliberate limit, stated in the code comment: on the grace-release branch both counters
equal the constants by construction (one write site each), so no test can prove the difference on
that line. The change buys one source of truth, not provable coverage. The place nudges genuinely
varies with the run is the /clear-timeout warn, which is covered by a discriminating test.
2026-09-12 04:44:10 +02:00
2 changed files with 164 additions and 16 deletions
@@ -15,6 +15,7 @@ import java.util.Set;
import java.util.concurrent.CompletableFuture;
import java.util.concurrent.ConcurrentHashMap;
import java.util.function.Consumer;
import java.util.function.LongSupplier;
import java.util.function.Predicate;
import java.util.stream.Collectors;
@@ -94,6 +95,14 @@ public final class Injector {
private final TurnListener turnListener;
private final Predicate<String> ready; // CB-113: a target is deliverable only when available
private final Consumer<String> forget; // CB-114: clear a gone worker's readiness/presence
/**
* Wall-clock source for the readiness-grace elapsed time logged in {@link #onStatus} (fleetd
* #501). Production constructors default this to {@code System::currentTimeMillis}; the
* package-private constructors below take it explicitly so a test can supply a stub whose
* advance does not track {@link #POLL_INTERVAL_MILLIS} — copying the shape {@code LeadRollover}
* already uses for the same purpose.
*/
private final LongSupplier nowMillis;
private final ConcurrentHashMap<String, Target> targets = new ConcurrentHashMap<>();
/** Delivery only; completion signalling is a no-op and every target is treated as available. */
@@ -125,20 +134,34 @@ public final class Injector {
*/
public Injector(AgentControl agents, TurnListener turnListener, Predicate<String> ready,
Consumer<String> forget) {
this(agents, turnListener, ready, forget, System::currentTimeMillis);
}
/** Full constructor — for tests: an injectable wall-clock supplier (fleetd #501). */
Injector(AgentControl agents, TurnListener turnListener, Predicate<String> ready,
Consumer<String> forget, LongSupplier nowMillis) {
this.agents = agents;
this.router = null;
this.turnListener = turnListener;
this.ready = ready;
this.forget = forget;
this.nowMillis = nowMillis;
}
public Injector(HerdrRouter router, TurnListener turnListener, Predicate<String> ready,
Consumer<String> forget) {
this(router, turnListener, ready, forget, System::currentTimeMillis);
}
/** Full constructor — for tests: an injectable wall-clock supplier (fleetd #501). */
Injector(HerdrRouter router, TurnListener turnListener, Predicate<String> ready,
Consumer<String> forget, LongSupplier nowMillis) {
this.agents = null;
this.router = router;
this.turnListener = turnListener;
this.ready = ready;
this.forget = forget;
this.nowMillis = nowMillis;
}
private AgentControl agentsFor(String target) {
@@ -209,6 +232,7 @@ public final class Injector {
int unknownSinceTurn; // consecutive `unknown` samples while a delegation is outstanding (CB-109)
int unknownSincePostTurn; // the same, for the post-turn housekeeping phase (fleetd #306)
int notReadySincePoll; // consecutive injectable samples a queued message waited on the readiness gate (CB-114)
long notReadySinceMillis; // wall-clock time of the FIRST non-ready sample in the current notReadySincePoll streak (fleetd #501); reset alongside it
boolean postTurnPending; // completion observed; adapter housekeeping has not started yet
boolean awaitingPostTurnPickup;
boolean postTurnObserved;
@@ -302,6 +326,7 @@ public final class Injector {
t.unknownSinceTurn = 0;
t.unknownSincePostTurn = 0;
t.notReadySincePoll = 0;
t.notReadySinceMillis = 0;
if (t.awaitingCompletion) t.turnObserved = true;
} else if (status.injectable()) { // IDLE or BLOCKED
t.unknownSinceTurn = 0;
@@ -353,6 +378,7 @@ public final class Injector {
Pending p = t.queue.peek();
if (p != null && ready.test(target)) {
t.notReadySincePoll = 0;
t.notReadySinceMillis = 0;
try {
agentsFor(target).send(target, p.text());
t.queue.poll();
@@ -370,23 +396,52 @@ public final class Injector {
sent = p;
sendError = e;
}
} else if (p != null && ++t.notReadySincePoll >= READINESS_GRACE_POLLS) {
// The worker has been idle-but-not-ready for the whole grace: its Claude
// never connected the bridge MCP (crashed during boot, or wedged on a
// startup prompt). The readiness gate would hold this message forever, so
// fail every queued message and release the target (CB-114) instead of
// polling it indefinitely with the caller's future never completing.
notReady = new ArrayList<>(t.queue);
for (Pending pending : notReady) {
pending.state = Pending.State.NOT_DELIVERED;
} else if (p != null) {
// fleetd #501: stamp the wall-clock time of the FIRST non-ready sample in
// this streak, so the expiry log below can print how long the target
// actually sat non-ready — not just how many polls that took.
if (t.notReadySincePoll == 0) {
t.notReadySinceMillis = nowMillis.getAsLong();
}
if (++t.notReadySincePoll >= READINESS_GRACE_POLLS) {
// The worker has been idle-but-not-ready for the whole grace: its Claude
// never connected the bridge MCP (crashed during boot, or wedged on a
// startup prompt). The readiness gate would hold this message forever, so
// fail every queued message and release the target (CB-114) instead of
// polling it indefinitely with the caller's future never completing.
notReady = new ArrayList<>(t.queue);
for (Pending pending : notReady) {
pending.state = Pending.State.NOT_DELIVERED;
}
// fleetd #501: t.notReadySincePoll — the loop's own counter, already in
// scope — is printed here instead of the READINESS_GRACE_POLLS constant.
// On this branch the counter has JUST reached the threshold, so the two
// agree by construction and no test can tell them apart. Printed anyway:
// it gives this line one source of truth instead of two, so a later
// change to the loop above cannot leave this message reporting a number
// the loop no longer produces.
//
// elapsedMillis is a different case: it is NOT equal-by-construction to
// the truth. notReadySincePoll only increments on a sample that reaches
// this branch (p != null, not ready) — a poll that misses that condition
// advances real time without advancing the counter — and this loop's real
// period is not guaranteed to equal POLL_INTERVAL_MILLIS (load, or a host
// sleep, can widen the real gap far past it). READINESS_GRACE_POLLS *
// POLL_INTERVAL_MILLIS / 1000 is arithmetic on two constants, not a
// measurement, so it stays here only as the labelled CONFIGURED budget,
// never presented as elapsed time.
long elapsedMillis = nowMillis.getAsLong() - t.notReadySinceMillis;
log.warn("readiness grace for {} expired after {} polls (configured={} "
+ "polls/{}s elapsed={}ms): target never became "
+ "deliverable, so failing {} queued message(s) that "
+ "never reached its pane",
target, t.notReadySincePoll, READINESS_GRACE_POLLS,
READINESS_GRACE_POLLS * POLL_INTERVAL_MILLIS / 1000, elapsedMillis,
notReady.size());
t.queue.clear();
t.notReadySincePoll = 0;
t.notReadySinceMillis = 0;
}
log.warn("readiness grace for {} expired after {} polls ({}s): target never "
+ "became deliverable, so failing {} queued message(s) that never "
+ "reached its pane",
target, READINESS_GRACE_POLLS,
READINESS_GRACE_POLLS * POLL_INTERVAL_MILLIS / 1000, notReady.size());
t.queue.clear();
t.notReadySincePoll = 0;
}
}
}
@@ -19,6 +19,8 @@ import java.util.Set;
import java.util.concurrent.CompletableFuture;
import java.util.concurrent.ExecutionException;
import java.util.concurrent.TimeUnit;
import java.util.concurrent.atomic.AtomicInteger;
import java.util.function.LongSupplier;
import static org.junit.jupiter.api.Assertions.*;
@@ -521,6 +523,97 @@ class InjectorTest {
}
}
@Test
void readinessGraceExpiryLogsTheMeasuredPollCountNextToTheConfiguredBudget() {
// fleetd #501, defect 1: READINESS_GRACE_POLLS (240) used to be printed twice — once as
// "after {} polls" and once inside the parenthesised budget — even though the loop's own
// counter (Target.notReadySincePoll) was in scope at the same call site. On THIS branch the
// counter has just reached the threshold, so it equals the constant by construction and this
// test cannot tell the two apart — it only pins that the message still carries both a poll
// count and a labelled configured budget, using literal numbers (240, 60), never
// READINESS_GRACE_POLLS or POLL_INTERVAL_MILLIS, so the assertion can't silently track a
// constant change instead of catching a real regression.
LoggerContext ctx = (LoggerContext) LoggerFactory.getILoggerFactory();
ch.qos.logback.classic.Logger injectorLog =
(ch.qos.logback.classic.Logger) LoggerFactory.getLogger(Injector.class);
ListAppender<ILoggingEvent> appender = new ListAppender<>();
appender.setContext(ctx);
appender.start();
injectorLog.addAppender(appender);
injectorLog.setLevel(Level.WARN);
try {
Injector inj = new Injector(new AgentControl(herdr), TurnListener.NOOP, _ -> false, _ -> {
});
inj.enqueue(T, "task", TestTurnTokens.inert(T));
for (int i = 0; i < READINESS_SAMPLES; i++) inj.onStatus(T, AgentStatus.IDLE);
String warn = appender.list.stream()
.filter(e -> e.getLevel().equals(Level.WARN))
.map(ILoggingEvent::getFormattedMessage)
.findFirst()
.orElse("no grace-expiry WARN logged");
assertTrue(warn.contains("after 240 polls"),
"must print the measured poll count as a plain number: " + warn);
assertTrue(warn.contains("configured=240 polls/60s"),
"must print the configured budget, clearly labelled: " + warn);
} finally {
injectorLog.detachAppender(appender);
}
}
@Test
void readinessGraceExpiryLogsTheMeasuredElapsedTimeNotArithmeticOnConstants() {
// fleetd #501, defect 2: the old line computed "({}s)" as READINESS_GRACE_POLLS *
// POLL_INTERVAL_MILLIS / 1000 — arithmetic on two constants, never a measurement, and wrong
// in the direction that says everything ran on schedule. This stub clock returns two FIXED
// values (1_000ms at the first non-ready sample, 318_412ms at the poll that trips the grace)
// whose difference — 317_412ms — does NOT equal 240 * POLL_INTERVAL_MILLIS (=60_000ms).
// Asserting on that literal, non-derived number is what makes this test able to fail if the
// production code goes back to printing the constant-arithmetic value instead of the
// injected clock's measurement.
long[] readings = {1_000L, 318_412L};
AtomicInteger call = new AtomicInteger(0);
LongSupplier stubClock = () -> {
int i = call.getAndIncrement();
if (i >= readings.length) {
throw new AssertionError("nowMillis read more times than this fixture expects (" + i
+ "); the readiness-not-ready branch should read the clock exactly twice — "
+ "once to stamp the first non-ready sample, once at grace expiry");
}
return readings[i];
};
LoggerContext ctx = (LoggerContext) LoggerFactory.getILoggerFactory();
ch.qos.logback.classic.Logger injectorLog =
(ch.qos.logback.classic.Logger) LoggerFactory.getLogger(Injector.class);
ListAppender<ILoggingEvent> appender = new ListAppender<>();
appender.setContext(ctx);
appender.start();
injectorLog.addAppender(appender);
injectorLog.setLevel(Level.WARN);
try {
Injector inj = new Injector(new AgentControl(herdr), TurnListener.NOOP, _ -> false, _ -> {
}, stubClock);
inj.enqueue(T, "task", TestTurnTokens.inert(T));
for (int i = 0; i < READINESS_SAMPLES; i++) inj.onStatus(T, AgentStatus.IDLE);
String warn = appender.list.stream()
.filter(e -> e.getLevel().equals(Level.WARN))
.map(ILoggingEvent::getFormattedMessage)
.findFirst()
.orElse("no grace-expiry WARN logged");
assertTrue(warn.contains("elapsed=317412ms"), "must print the MEASURED elapsed time from "
+ "the injected clock (318412 - 1000 = 317412), not an arithmetic value: " + warn);
assertFalse(warn.contains("elapsed=60000ms"), "must not print "
+ "READINESS_GRACE_POLLS * POLL_INTERVAL_MILLIS (240 * 250 = 60000ms) as if it "
+ "were the measured elapsed time: " + warn);
} finally {
injectorLog.detachAppender(appender);
}
}
@Test
void aWorkerThatBecomesReadyWithinTheGraceIsDeliveredNormally() {
// The readiness grace must not fail a worker that is merely slow to boot: once it becomes