Dai Ha 2fb46f670f CB-114: readiness-gate timeout + presence cleanup (delegated review findings)
An off-sub worker's review of CB-113 (delegated through the bridge) surfaced two
real gaps in the readiness gate:

- A worker that herdr reports idle but whose Claude never connects the bridge MCP
  (crashed during boot, or wedged on a startup prompt) left its message queued
  forever: ready.test() never passed, the target was polled indefinitely, and the
  caller's future never completed (async waiter hung for the full 30-min window).
  Injector now counts injectable-but-not-ready samples and, after a ~60s grace
  (READINESS_GRACE_POLLS, deliberately longer than the UNKNOWN stall grace since a
  first boot is slower than an in-turn blip), fails the queued messages, fires
  onTurnFailed so blocking/async waiters resolve WORKER_FAILED, and reclaims the
  target. Mirrors the CB-109 UNKNOWN-stall path.

- WorkerPresence.forget had no caller, so a worker's readiness lingered past its
  life. Injector now clears presence via a forget callback on drop() (pane crash)
  and on the readiness timeout.

+3 InjectorTest cases (never-ready failure, ready-within-grace delivery, drop clears
presence). 105 tests green.